Low waste 2:1

Official manufacturerMEMBROM® · 32 years in manufacturing

Commercial 2:1 low-waste direct-flow reverse osmosis 72 L/h anti-bacterial (20″)

Anti-bacterial commercial system that produces 2 litres of pure water for every litre rejected, with no tank and water on demand.

MEMBROM® · ref. OI-PR-2:1-12-NX-AB20
72 L/h2:1 ratioAnti-bacterialStainless steel3-year warranty

Price range: €584.33 through €744.19

21% VAT and shipping included · Ships in 24/48h

Free 24/48h shippingSame-day dispatch (mainland Spain)
3-year warrantyCE certified · EU design
Secure paymentCard · invoice issued
Made in SpainOwn patent · R&D
Up to 8 yearsfilter life
95–99%solids removed
72 L/hdirect flow, no tank
Anti-bacterialno disinfection
Commercial 2:1 low-waste reverse osmosis with a direct flow of 72 litres/hour, fully anti-bacterial (model OI-PR-2:1-12-NX-AB20). It produces 2 litres of pure water for every litre rejected — twice the efficiency of a conventional reverse osmosis system — with no tank and water ready instantly.

3 L in

→

2 L pure

1 L waste

Direct-flow output

At least 1.2 L/min (72 L/h) with no tank, enough for most home and commercial uses.

High-quality water

Removes between 95 and 99% of dissolved solids, even in very hard water, and maintains quality over thousands of litres.

Bacteriological protection

Anti-bacterial sediment filters, carbon filters and filter housings: they can be used to the end of their service life with no need for disinfection.

Minimal maintenance

High-adsorption carbon block (36,000 L certified). The pre-filters protect the membranes and use can be extended up to 8 years.

No post-filter needed

Pre-filtration removes taste, odour, chlorine, colour and volatile organic compounds, so there’s no need to add a post-filter.

Precision filtration

Membranes with FILMTEC™ sheet (USA), carbon tested with 2 ppm of chlorine and sediment filters with 82–99% semi-absolute retention.

Everything included with the system

  • Filters and membranes
  • 5 m of tubing
  • Spanners
  • Standard Spanish water connection
  • Drain saddle
  • Tap or valve
  • Adapter
  • Manual
  • CE certified

Technical specifications

ModelOI-PR-2:1-12-NX-AB20
Product / waste ratio2 : 1 (67% recovery)
Flow rate1.2–1.6 L/min (72–96 L/h)
Daily output (12 h, intermittent)864–1.152 L
Operation1 h continuous · up to 12 h/day in cycles
Inlet pressure1.5–7 bar (no pressure reducer)
Max. dissolved solids (raw water)2,000 ppm
Solids removal95–99% hard · 90–95% soft
Chlorine removal99.99% at start / 90% at end
Particle retention82–99% semi-absolute (5–10 µm)
Connections3/8″ inlet · 1/4″ product and waste
Dimensions395 × 210 × 810 mm
Membranes4 × MEMBROM 1812-200
Carbon filtersCA-AB-20-36 (anti-bact.)
Sediment filtersFS-SA-AB-82-20-5 (anti-bact.)
Filter housings / membrane housingsAnti-bacterial 8 bar · anti-bacterial membrane housings 8 bar
Power consumption30 W running · 0 W on standby
Power supplyLow voltage with external adapter
BracketStainless steel
Warranty3 years · CE certified
ManufactureSpain · EU registered design

Monitoring and safety

  • Pressure monitoring: three gauges (bar and psi) measure how clogged the sediment filter is and the pressure at the membranes.
  • Quality meter (optional): compares inlet and outlet in TDS (ppm) or EC (µS); 1 m probes, battery-powered, switches off automatically after 5 minutes.
  • Flow meters with counters (optional): on the waste and/or product line; they alternate between cumulative litres and instantaneous flow and warn you when the batteries run low.
  • Electrical safety: low-voltage pump, solenoid valve and pressure switches. It starts and stops when you open and close the tap; on standby it uses no electricity.
  • Easy carbon flushing: a valve system diverts loose carbon to the drain when starting up or replacing filters, and lets you take samples and depressurise the system.

Filter and membrane lifespan

With drinkable, chlorinated feed water, the sediment and carbon pre-filters last up to 8 years, or 36,000 L. The membranes usually last longer if the pre-filters are replaced on time. Estimated lifespan in years by daily consumption:

Consumption (L/day)20″ filters · 36,000 L
38
58
88
106,58
154,38
203,29
252,63
302,19
351,88
501,32
750,88
1000,66
1500,44
2000,33
3000,22
4000,16
5000,13
7500,09
10000,07
11520,06

Maximum recommended use: 8 years. For non-chlorinated water or water with bacteriological contamination, please contact us.

Applications

Thanks to its approved design and bacteriological protection, it is suitable for demanding environments where purity and water savings matter.

Home
Hospitality
Food industry
Laboratory
Medical / pharma
Aquariums
Hydroponics

Certificates, quality and warranty

Raw materials certified for contact with drinking water and for the food and medical industries, complying with European and US standards.

CENSFFDAUNE 149101GMPOwn patent

System with a 3-year warranty, designed and made in Spain, with an industrial design registered in the European Union and innovations described in our own patent. Assembled in our workshops in Nigrán (Pontevedra) with stainless steel fixings and quick-connect fittings.

Frequently asked questions

What does “2:1 low waste” mean?+
It produces 2 litres of pure water for every litre rejected (67% recovery), compared with the 3–4 litres a conventional reverse osmosis system wastes for every useful litre.
Does it need a tank?+
No. It is a direct-flow system: it produces at least 1.2 L/min and the water comes straight out of the tap, with no waiting and no tank taking up space.
How often are the filters changed?+
The pre-filters last up to 8 years, or 36,000 L, provided the feed water is drinkable and chlorinated. The membranes usually last considerably longer if the pre-filters are replaced on time. For non-chlorinated water or water with bacteriological contamination, please contact us.
What water pressure does it need?+
It works with an inlet pressure of between 1.5 and 7 bar and needs no pressure reducer. It accepts raw water with up to 2,000 ppm of dissolved solids.
Which options can I configure?+
Water quality meter (EC conductivity meter, TDS ppm meter, no meter); tap or valve (stainless steel tap, ball valve); flow meters with counters (1 flow meter, 2 flow meters, no flow meters).